ABSORBANCE SPEC PACK / ABSORBANCE SPEC PACK CUV
The Absorbance Full Pack CUV is an affordable and flexible solution for using traditional cuvettes in Absorbance measurements.
This configuration uses a SPEC RES+ UV/Vis/NIR spectrometer with 10 µm slit, granting an optical resolution of 0.75 nm and wavelength range of 200-1050 nm.
The Light Source LS-DW is an high stability light source, emitting from 200-1100 nm with shutter and external or local control. The solution is complete with 600 µm core diameter Optical Fibers (50 cm length) and a Cuvette Holder for Absorbance with 6 mm Collimating Lens.
ABSORBANCE SPEC PACK / ABSORBANCE SPEC PACK PROBE
The Absorbance SPEC Pack PROBE is quite useful when the user is unable to place the sample into a cuvette or use a flow cell. In situations where the reaction needs to be screened inside a vessel or reactor, the Absorbance SPEC Pack is the perfect solution.
Includes a Spec RES+ UV/Vis/NIR with 10 µm slit for 0.75 nm optical resolution and wavelength range of 200-1050 nm, light source LS-DW with high stability and emission from 200 to 1100 nm and Transmission Probe with 600 µm core diameter.
ABSORBANCE SPEC PACK / ABSORBANCE SPEC PACK FLOW
Flow measurements are one of the best cases to take advantage of the full spectrum vs. time acquisition available in all SPEC spectrometers when using the high flexibility of Kinetics Module from LightScan Software. This solution has been used in applications such as Flow Injection Analysis (FIA) and as an HPLC (High Pressure Liquid Chromatography) detector with great results and affordable price.
The configuration uses a SPEC STD UV/Vis/NIR enhanced sensitivity with wavelength range from 200-1050 nm, 25 µm slit with an optical resolution of 1.7 nm and minimum integration time of 2 ms for fast sample screening. Together with the light source LS-DWHP emitting from 200 to 1100 nm, the Z format flow cell FCAPE / FCASS with 1 cm path length and optical fibers with 600 µm core diameter for maximum sensitivity.
1. SPEC STD
• Detection from 180-1100 w/ 2048 pixels linear detector CCD array | • Minimum integration time of 2 ms |
• Triggering functions for easy integration (trigger in/out and delay) | • Portable, fast and small size |
• High speed mini USB 2.0 for power and control | • Software LightScan included |
• Also available as an OEM instrument | • SMA 905 fiber connector, no optical alignment required |
• Robust: fully built in aluminium | • LED backlight indicator |
When looking for an affordable and flexible spectrometer the SPEC STD range is the best option. With detection from 180 to 1100 nm, it can be used in Absorbance, Transmittance, Reflectance, Irradiance, Color and Fluorescence measurements.
2. SPEC RES+
• Detection from 180 to 1100 nm | • High speed mini USB 2.0 for power and control |
• 3648 pixels linear array CCD detector | • Also available as an OEM instrument |
• Great optical resolution of 0.2 nm in a standard configuration | • SMA 905 fiber connector, no optical alignment required |
• Triggering functions for easy integration (trigger in/out and delay) | • Robust: fully built in alluminium |
• Portable, fast and small size | • LED Backlight indicator |
For users looking for an affordable spectrometer with great resolution Sarspec offers the SPEC RES+ spectrometers range. With the best resolution/wavelength range ratio for a miniature CCD spectrometer the SPEC RES+ is the best option for Absorbance and Transmittance measurements as well for high throughput light source characterization.
3. SPEC SENSE+
• Largest sensitive area, using 1000 µm height pixels | • Back thinned CCD array detector with 2048 pixels |
• Detection from 200-1100 nm | • Great sensitivity and quantum efficiency up to 78% |
• Great performance in the UV | • Triggering functions for easy integration and synchronization |
• SMA 905 fiber connector, no optical alignment required | • High speed mini USB for full control of the spectrometer |
• Software LightScan included | • Fully built in aluminium with LED backlight indicator |
Sarspec’s SPEC SENSE+ is a spectrometer specially built for low light level measurements such as Fluorescence and Raman but it also has the flexibility to be used in Absorbance, Transmittance, Irradiance and Reflectance measurements.
4. SPEC SPEED+
• Fast acquisition rate up to 2857 spectra per second using burst mode | • 2 µs integration time with electronic shutter |
• Back thinned CCD array detector with 2048 pixels | • Largest sensitive area, using 1000 µm height pixels |
• Detection from 200-1100 nm | • Great sensitivity and quantum efficiency up to 78% |
• Trigger functions for easy integration and synchronization | • SMA 905 fiber connector, no optical alignment required |
• High speed mini USB for full control of the spectrometer | • Software LightScan+ Included |
• Fully built in Alluminium with LED backlight indicator | |
With minimum integration time of 2 µs the SPEC SPEED+ is faster than any other spectrometer available using a CCD array. It was specially built for microseconds events including fast kinetics in chemical reactions, ignition processes and fluorescence monitoring among a large number of applications that need fast analysis.