- Large easy to read TFT display for better image quality and easy navigation
- Integrated weighing funktion
- Torque trend measurement indicates changes in product viscosity
- Integrated pH sensor connection
- RS 232 and USB interface to operate the unit with the laboratory software labworldsoft
- Standard joint fittings on the lid: 2 x NS 29, 2x NS 14, 2 x GL 14 for flexible adaptation of further equipment
- Expandable for use with the ULTRA- TURRAX® T 25 digital (Accessory)
- Vacuum valve included with delivery
- Anchor stirrer with PTFE-scrapers
- Connections to attach a cooling source to the back of the unit
- Manual adjustable safety circuit
- Integrated safety shutdown when vessel or lid is removed from the base
Usable volume max. | 1000 ml |
Usable volume with disperser tool min. | 300 ml |
Usable volume without disperser tool min. | 500 ml |
Working temperature max. | 120 °C |
Attainable vacuum | 25 mbar |
Viscosity max. | 100000 mPas |
Speed range | 10 – 150 rpm |
Support rod diameter (with integrated fastening on stand) | 16 mm |
Material in contact with medium | AISI 316L, 1.4571, borosilicate glass 3.3, PTFE, PEEK, FKM |
Reactor vessel openings (units/standard) | 2x NS 29/32, 2x NS 14/23 & 2x GL 14 |
Permissible ON time | 100 % |
Temperature measurement resolution | 0.1 K |
Nominal torque | 3 Nm |
Heat output | 1000 W |
Cooling medium permissible operating pressure | 1 bar |
Weighing range max. | 2000 g |
Weighing resolution | 1 g |
Speed min (adjustable) | 10 rpm |
Heating temperature max. | 180 °C |
Adjustable safety circuit, upper temperature value | 225 °C |
Adjustable safety circuit, lower temperature value | 47 °C |
Adjustable safety circuit, upper temperature value deviation | 20 ±K |
Adjustable safety circuit, lower temperature value deviation | 10 ±K |
Cooling medium temperature min. | 3 °C |
Set temperature resolution | 1 ±K |
Heat control accuracy of medium with sensor | 0.2 ±K |
Speed deviation | 5 ±rpm |
Speed display | TFT |
Heat control | TFT |
Connection for ext. temperature sensor | PT 100 |
Stirring element fastening | special output shaft |
Torque display | yes |
Torque measurement | trend |
Timer | yes |
Timer display | TFT |
Speed control | 1 RPM steps |
Type of cooling | flow |
Temperature display | yes |
Working temperature sensor | PT 100 |
Safety temperature sensor | PT1000 |
Working temperature display | TFT |
Safety temperature display | TFT |
Display for operation with ext. sensor | yes |
Safety cutout | yes |
Reversible direction of rotation | no |
pH meter interface | yes |
pH value display | TFT |
Dimensions (W x H x D) | 443 x 360 x 295 mm |
Weight | 16 kg |
Permissible ambient temperature | 5 – 40 °C |
Permissible relative humidity | 80 % |
Protection class according to DIN EN 60529 | IP 21 |
RS 232 interface | yes |
USB interface | yes |
Analog output | no |
Voltage | 230 / 115 V |
Frequency | 50/60 Hz |
Power input | 1200 W |